# Format: STATUSCODE=English description
# Decimal base status; suffix -10 adds the intermittent flag.

00-00=No additional information
07-00=Signal too low
06-00=Signal too high
10-00=Lower adaptation limit not reached
16-00=Signal out of range
27-00=Implausible signal
29-00=Short to ground
30-00=Open circuit or short to B+
35-00=No additional information
25-00=Undefined switch state
49-00=No communication
01-00=Signal shorted to positive supply
02-00=Signal shorted to ground
03-00=Signal missing
04-00=Mechanical fault
05-00=Input circuit open
08-00=Upper control limit exceeded
09-00=Upper adaptation limit exceeded
11-00=Lower control limit not reached
17-00=Control deviation
20-00=Basic setting fault
26-00=Output circuit open
28-00=Short to positive supply
31-00=Open circuit or short to ground
32-00=Excessive resistance
33-00=Insufficient resistance
34-00=Additional information unavailable
36-00=Open circuit
37-00=Malfunction
38-00=Output does not switch or is shorted to positive supply
39-00=Output does not switch or is shorted to ground
40-00=Short to another output
41-00=Blocked or voltage absent
42-00=Excessive speed deviation
43-00=Closed
44-00=Short circuit
45-00=Connector
46-00=Leakage
47-00=Communication missing or connection incorrect
48-00=Supply voltage